1 # This is the "standard" charging config for Mot C1xx phones running
2 # FreeCalypso fw. The start threshold is set to "always" on the reasoning
3 # that if the user connects the charging power source (which is not USB
4 # and thus not required for computer connection), it means that she
5 # actually intends to charge the battery, the charge-to voltage is the
6 # full charge (charge the battery fully before going out), and the
7 # restart threshold is a reasonable setting so if the phone is left
8 # plugged into the charger for a long time, the user won't be surprised
9 # with a battery that has run down significantly after the completion
10 # of the initial charging cycle.
11
12 start-threshold always
13 restart-threshold 3900 # mV
14 charge-to-voltage 4200 # mV
15 overvoltage 4280 # mV
16
17 # For the current settings, keep in mind that C1xx phones use a current
18 # measurement resistor of 0.15R instead of TI's "canonical" value of 0.20R,
19 # hence the conversion factor between mA and ADC/DAC numbers changes
20 # accordingly. The CI current setting is based on what Motorola's fw
21 # has been observed to set, but the end current setting is our own.
22
23 ci-current 280 # DAC units, about 320 mA
24 end-current 88 # ADC units, about 100 mA
25
26 # Motorola's fw does not seem to use the I2V offset mechanism,
27 # but we use the same setting as Pirelli.
28
29 i2v-offset 0x18 # register setting