CST: remove AT%Nxxxx old AEC control This crude method of enabling and configuring AEC is not compatible with L1_NEW_AEC, and even for the old AEC it did not support every possible combination. It is time for this hack to go. The new and proper way of enabling and configuring AEC is via RiViera Audio Service audio mode facility, either audio mode files or full access write, most directly accessible via fc-tmsh auw 12 for free experimentation.
author Mychaela Falconia <falcon@freecalypso.org>
date Thu, 29 Jul 2021 18:57:36 +0000
parents 35f7a1dc9f7d
children
line wrap: on
line source

;********************************************************************************
;*** File           : mnlc.pdf
;*** Creation       : Wed Mar 11 09:58:25 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : mnlc
;*** Document No.   : 8443.104.02.003
;*** Document Date  : 2002-10-25
;*** Document Status: SUBMITTED
;*** Document Author: TML
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:48:12 2007"
PRAGMA 	LAST_MODIFIED 	"2002-10-25"
PRAGMA 	ID_AND_VERSION 	"8443.104.02.003"



CONST 	L_MAX_CALLED_BCD_NO_LENGTH 	10 	; Max Bcd number length (digits)
CONST 	CURSOR_SMS_TEXT_140 	140 	; Position SMS Message



VALTAB 	VAL_data_valid
VAL 	0 	DATA_VALID 	""
VAL 	1 	DATA_INVALID 	""




VAR 	reference 	"Reference" 	S


VAR 	bcd 	"Bcd Number" 	B


VAR 	data_valid 	"Cursor Data Valid" 	B

VAL 	@p_mnlc - VAL_data_valid@ 	

VAR 	number_length 	"Number of decimal digits in the Bcd number" 	B


VAR 	sms_text 	"SMS text" 	B





COMP 	called_party_bcd_num 	 "called Party Bcd number"
{
 	number_length 	 ; Number Length
 	bcd 	[L_MAX_CALLED_BCD_NO_LENGTH] 	 ; Bcd Number
}






; MNLC_SMS_MEAS_REQ 	0x80000044
; MNLC_SMS_MEAS_CNF 	0x80004044



PRIM 	MNLC_SMS_MEAS_REQ 	0x80000044
{
 	reference 	 ; Reference SMS request
 	called_party_bcd_num 	 ; Called Bcd Number
}






PRIM 	MNLC_SMS_MEAS_CNF 	0x80004044
{
 	reference 	 ; Reference SMS request
 	data_valid 	 ; Cursor Data Valid
 	sms_text 	[CURSOR_SMS_TEXT_140] 	 ; Cursor SMS
}