view cdg-hybrid/msg/tst.mdf @ 274:fa22012c4a39

CST: remove AT%Nxxxx old AEC control This crude method of enabling and configuring AEC is not compatible with L1_NEW_AEC, and even for the old AEC it did not support every possible combination. It is time for this hack to go. The new and proper way of enabling and configuring AEC is via RiViera Audio Service audio mode facility, either audio mode files or full access write, most directly accessible via fc-tmsh auw 12 for free experimentation.
author Mychaela Falconia <falcon@freecalypso.org>
date Thu, 29 Jul 2021 18:57:36 +0000
parents 35f7a1dc9f7d
children
line wrap: on
line source

;********************************************************************************
;*** File           : tst.mdf
;*** Creation       : Thu Jun 19 15:32:14 CST 2008
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Air Interface Message Specification
;*** Document Name  : tst
;*** Document No.   : 8441.603.99.005
;*** Document Date  : 2000-10-23
;*** Document Status: BEING_PROCESSED
;*** Document Author: ANS
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Wed Nov 28 10:21:30 2007"
PRAGMA 	LAST_MODIFIED 	"2000-10-23"
PRAGMA 	ID_AND_VERSION 	"8441.603.99.005"



CONST 	L3MAX 	251 	; maximum size of a L3 buffer
CONST 	MAX_N_PDU_NUMBER_LIST 	11 	; maximum size of N-PDU number list



VALTAB 	VAL_no_of_pdus
VAL 	DEF 	 	"Number of PDUs to transmit"
VAL 	0 	TEST_INFINITIVE_NO 	"ciphering not used"

VALTAB 	VAL_dl_timeslot_offset
VAL 	0 	TEST_TN0 	"downlink timeslot offsett 0"
VAL 	1 	TEST_TN1 	"downlink timeslot offsett 1"
VAL 	2 	TEST_TN2 	"downlink timeslot offsett 2"
VAL 	3 	TEST_TN3 	"downlink timeslot offsett 3"
VAL 	4 	TEST_TN4 	"downlink timeslot offsett 4"
VAL 	5 	TEST_TN5 	"downlink timeslot offsett 5"
VAL 	6 	TEST_TN6 	"downlink timeslot offsett 6"
VAL 	7 	TEST_TN7 	"downlink timeslot offsett 7"

VALTAB 	VAL_mode_flag_val
VAL 	0 	TEST_RANDOM 	"pseudorandom data"
VAL 	1 	TEST_LOOP 	"loop back"




VAR 	msg_type 	"Message Type" 	
 	8


VAR 	no_of_pdus 	"Number of PDUs" 	
 	12

VAL 	@m_tst - VAL_no_of_pdus@ 	

VAR 	dl_timeslot_offset 	"Downlink Timeslot Offset" 	
 	3

VAL 	@m_tst - VAL_dl_timeslot_offset@ 	

VAR 	mode_flag_val 	"Mode Flag Value" 	
 	1

VAL 	@m_tst - VAL_mode_flag_val@ 	




COMP 	pdu_description 	"PDU Description"
{
 	.000  ; spare
 	 	no_of_pdus 	 ; Number
}



COMP 	pdu_description_ie 	"PDU Description IE"
{
 	CSN1_S1  	pdu_description 	 ; PDU Description
}



COMP 	mode_flag 	"Mode Flag"
{
 	.0000  ; spare
 	 	dl_timeslot_offset 	 ; Downlink Timeslot Offset
 	 	mode_flag_val 	 ; Mode Flag Value
}






MSG 	gprs_test_mode_cmd 	downlink 	36 ; gprs_test_mode_cmd
{
 	GSM3_V  	msg_type 	 ; Message Type
 	GSM3_V  	pdu_description_ie 	 ; PDU description
 	GSM3_V  	mode_flag 	 ; Mode Flag
}