abb_inth.c: check all interrupt causes, not just one
The original code used if - else if - else if etc constructs, thus
the first detected interrupt was the only one handled. However,
Iota ITSTATREG is a clear-on-read register, thus if we only handle
the first detected interrupt and skip checking the others, then the
other interrupts will be lost, if more than one interrupt happened
to occur in one ABB interrupt handling cycle - a form of rare race
condition. Change the code to check all interrupts that were read
in this cycle.
author | Mychaela Falconia <falcon@freecalypso.org> |
---|---|
date | Sun, 13 Jun 2021 18:17:53 +0000 |
parents | 35f7a1dc9f7d |
children |
line wrap: on
line source
;******************************************************************************** ;*** File : mnlc.pdf ;*** Creation : Wed Mar 11 09:58:25 CST 2009 ;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1 ;*** Copyright : (c) Texas Instruments AG, Berlin Germany 2002 ;******************************************************************************** ;*** Document Type : Service Access Point Specification ;*** Document Name : mnlc ;*** Document No. : 8443.104.02.003 ;*** Document Date : 2002-10-25 ;*** Document Status: SUBMITTED ;*** Document Author: TML ;******************************************************************************** PRAGMA SRC_FILE_TIME "Thu Nov 29 09:48:12 2007" PRAGMA LAST_MODIFIED "2002-10-25" PRAGMA ID_AND_VERSION "8443.104.02.003" CONST L_MAX_CALLED_BCD_NO_LENGTH 10 ; Max Bcd number length (digits) CONST CURSOR_SMS_TEXT_140 140 ; Position SMS Message VALTAB VAL_data_valid VAL 0 DATA_VALID "" VAL 1 DATA_INVALID "" VAR reference "Reference" S VAR bcd "Bcd Number" B VAR data_valid "Cursor Data Valid" B VAL @p_mnlc - VAL_data_valid@ VAR number_length "Number of decimal digits in the Bcd number" B VAR sms_text "SMS text" B COMP called_party_bcd_num "called Party Bcd number" { number_length ; Number Length bcd [L_MAX_CALLED_BCD_NO_LENGTH] ; Bcd Number } ; MNLC_SMS_MEAS_REQ 0x80000044 ; MNLC_SMS_MEAS_CNF 0x80004044 PRIM MNLC_SMS_MEAS_REQ 0x80000044 { reference ; Reference SMS request called_party_bcd_num ; Called Bcd Number } PRIM MNLC_SMS_MEAS_CNF 0x80004044 { reference ; Reference SMS request data_valid ; Cursor Data Valid sms_text [CURSOR_SMS_TEXT_140] ; Cursor SMS }