view cdg-hybrid/sap/cci.pdf @ 268:f2e52cab0a73

abb_inth.c: check all interrupt causes, not just one The original code used if - else if - else if etc constructs, thus the first detected interrupt was the only one handled. However, Iota ITSTATREG is a clear-on-read register, thus if we only handle the first detected interrupt and skip checking the others, then the other interrupts will be lost, if more than one interrupt happened to occur in one ABB interrupt handling cycle - a form of rare race condition. Change the code to check all interrupts that were read in this cycle.
author Mychaela Falconia <falcon@freecalypso.org>
date Sun, 13 Jun 2021 18:17:53 +0000
parents 35f7a1dc9f7d
children
line wrap: on
line source

;********************************************************************************
;*** File           : cci.pdf
;*** Creation       : Wed Mar 11 09:57:44 CST 2009
;*** XSLT Processor : Apache Software Foundation / http://xml.apache.org/xalan-j / supports XSLT-Ver: 1
;*** Copyright      : (c) Texas Instruments AG, Berlin Germany 2002
;********************************************************************************
;*** Document Type  : Service Access Point Specification
;*** Document Name  : cci
;*** Document No.   : 8441.118.00.017
;*** Document Date  : 2003-01-13
;*** Document Status: BEING_PROCESSED
;*** Document Author: UT
;********************************************************************************



PRAGMA 	SRC_FILE_TIME 	"Thu Nov 29 09:37:42 2007"
PRAGMA 	LAST_MODIFIED 	"2003-01-13"
PRAGMA 	ID_AND_VERSION 	"8441.118.00.017"






VALTAB 	VAL_algo_type
VAL 	0 	CCI_ALGO_V42 	"V42bis algorithm"

VALTAB 	VAL_comp_inst
VAL 	0 	CCI_COMP_INST_V42_0 	"first instance for V42bis"




VAR 	algo_type 	"algorithm type" 	B

VAL 	@p_cci - VAL_algo_type@ 	

VAR 	comp_inst 	"compressor instance" 	B

VAL 	@p_cci - VAL_comp_inst@ 	







; CCI_INIT_REQ 	0x3604



PRIM 	CCI_INIT_REQ 	0x3604
{
 	algo_type 	 ; algorithm type
 	comp_inst 	 ; compressor instance
}