| 64:65577bb967f7 | 65:e7b9a9903f14 |
|---|---|
| 66 | 66 |
| 67 Note that the LoCosto document indicates the use of a different signal generator | 67 Note that the LoCosto document indicates the use of a different signal generator |
| 68 level (-68.5 dBm instead of -74.5), and tells the operator to set the AGC gain | 68 level (-68.5 dBm instead of -74.5), and tells the operator to set the AGC gain |
| 69 to 0 dB. The latter must be a LoCosto-ism, as it is definitely not correct for | 69 to 0 dB. The latter must be a LoCosto-ism, as it is definitely not correct for |
| 70 our Calypso+Iota+Rita chipset. If we set the signal generator level to | 70 our Calypso+Iota+Rita chipset. If we set the signal generator level to |
| 71 -68.5 dBm, we would need to get the Rita AGC to 28 dB, but the Mother of | 71 -68.5 dBm, we would need to set the Rita AGC to 28 dB, but the Mother of |
| 72 FreeCalypso decided to go with the safer choice of using the Sara settings of | 72 FreeCalypso decided to go with the safer choice of using the Sara settings of |
| 73 -74.5 dBm generator level, 34 dB AGC. | 73 -74.5 dBm generator level, 34 dB AGC. |
| 74 | 74 |
| 75 FreeCalypso Rx calibration tools | 75 FreeCalypso Rx calibration tools |
| 76 ================================ | 76 ================================ |